Control User Manual Repack: V2000-c Rfid Access
(Note: this is an instructional and practical guide meant to complement the official user manual. Always consult the manufacturer’s manual and local regulations before installation.)
Whether you have just unboxed your device or you are troubleshooting an existing setup, here is a breakdown of the critical insights found in the V2000-C manual.
The V2000-C is a 125KHz RFID standalone access control keypad supporting up to 1,000 users with 4-digit PINs or EM cards. Featuring a Wiegand 26 interface and a 3-8 cm reading range, the weatherproof unit operates on 12VDC and includes relay outputs for locks and alarms. For detailed programming instructions and wiring diagrams, see the uAmper Manual .
Symptom: Valid card is swiped, green light turns on, but the door does not unlock. V2000-c Rfid Access Control User Manual
The V2000-C RFID access control system is a cutting-edge security solution designed to provide efficient and secure access management for various applications, including offices, residential areas, and industrial sites. This user manual aims to provide a comprehensive guide for users to understand the features, installation, configuration, and operation of the V2000-C RFID access control system.
The anti-tamper switch is located at the bottom right corner of the circuit board. When closed, the alarm is silent. When opened (cover removed), the buzzer emits continuous short beeps.
Normally Closed (NC) – Connects to Fail-Safe locks (unlocks when power is cut, like magnetic locks). (Note: this is an instructional and practical guide
Present a valid master card, enter the master code, or wait for the set alarm time to expire (Default 3 minutes). Door Open Detection (Door Status Monitoring) If wired to an external magnetic door sensor switch:
The V2000-C RFID access control system comes with a comprehensive user manual that provides detailed instructions on installation, configuration, and operation. Here are some key configuration steps:
If you forget the Master Code or wish to completely wipe the device settings, follow these steps: Turn off the power to the unit. Press and hold the # key while turning the power back on. Release the # key after hearing two short beeps. Featuring a Wiegand 26 interface and a 3-8
| LEDs | Status | Meaning | |:-----|:-------|:--------| | Red only | Steady | System powered, idle mode | | Green + Red | Flashing | Card reading in progress | | Orange + Red | Steady | In programming mode | | Red + Green + Orange | Flashing | Initialization mode | | Green | Flash once | Access granted |
Verify the card type is a 125kHz EM standard card. Mifare 13.56MHz cards are incompatible.
If you can tell me (magnetic or strike), I can tell you exactly which wiring diagram you need to follow. RFID Programming Guide
© 2018 - 2025 Brawl Time Ninja (b11a102) — Переведено translators
This content is not affiliated with, endorsed, sponsored, or specifically approved by Supercell and Supercell is not responsible for it. For more information see Supercell's Fan Content Policy: www.supercell.com/fan-content-policy.