Wittmann Tempro Plus D 360 Manual Instant

Allow the unit to automatically fill and vent air from the internal circuit. Set your desired target temperature on the display.

Connect a clean, filtered cooling water supply to the cooling inlet.

The Wittmann Tempro Plus D 360 is a premium, high-performance temperature control unit engineered to meet the most demanding requirements of the injection molding industry. Its powerful specifications, intuitive touch-screen interface, and advanced features like pressure control and oscilloscope recording provide exceptional process reliability and part quality. When combined with the complete instructions found in the official manual, this guide should serve as a foundation for operating, maintaining, and troubleshooting this advanced piece of equipment. For over 30 years, WITTMANN Tempro units have been a benchmark for reliability, and the D360 continues that legacy as a central component of the modern, efficient, and "Industry 4.0" ready injection molding cell. Wittmann Tempro Plus D 360 Manual

The Tempro Plus D 360 is designed for high-temperature water applications, eliminating the need for oil-based systems in specific temperature ranges. Key Equipment Specifications 360°C (680°F) Medium: Pressurized water

The unit will automatically engage the heaters or cooling valves to reach the target. Maintenance and Calibration Allow the unit to automatically fill and vent

Automatically monitors system integrity during filling and operation.

| Problem | Possible Cause | Solution | |----------------------|--------------------------------|-----------------------------------------------| | | PID settings incorrect | Run auto-tuning or reset to default PID values. | | Unit not heating | Heater relay failure | Check relay for welding; replace if necessary. | | Low pressure alarm | Water supply interruption | Ensure water supply is open and pressure is adequate. | | Error code E-01 | Sensor break or short circuit | Check temperature sensor and wiring; replace sensor. | | Unit shuts down randomly | Overheating due to poor cooling | Clean the cooling water filter and heat exchanger. | | Pump not running | Motor overload tripped | Reset the overload relay; check for blockage. | The Wittmann Tempro Plus D 360 is a

Connect the cooling water outlet to your plant's return line or drain.

Navigate to the service tab and choose the '121 times' menu. Select 'first filling max field' to enter the desired time. Changing Turn-Off Behavior

Running the pump without water will destroy the mechanical seal within 30 seconds.