Before touching any internal components, turn off the main power supply to the drive. Wait at least 5 to 10 minutes for the internal DC bus capacitors to discharge fully. Verify that the charge LED indicator on the drive is completely off. Step 2: Inspect and Reseat the Option Card Remove the front cover of the Yaskawa drive. Locate the communication or feedback option card.
The H66 code is categorized as an or a minor run command fault. Unlike major hardware faults (like CPF errors), H66 is often related to the external control signals being sent to the drive's digital inputs. Common Causes of H66
When the drive commands the motor to move, it expects to see a return signal (pulses) from the encoder.
[Power On Drive] ──> [Read Keypad Display: H66] ──> [Check Parameter H6-06] │ ┌───────────────────────────────────────────────────────┴──────────────────────────────────────────────────────┐ ▼ ▼ [H6-06 is set to 101, 102, 105, or 116] [H6-06 is set incorrectly] │ │ ▼ ▼ [Check Pulse Scaling Parameter] [Reprogram H6-06 value] │ │ ▼ ▼ [Change Value away from 0] ──> [Cycle Control Power] ──> [Verify ALM LED Clears] ───────────────────────> [Run Motor Test] Step 1: Verify the Configuration of H6-06 Stop all run commands to the drive. yaskawa error code h66
Yaskawa’s engineering team can provide a or identify a hardware defect (e.g., failed current sensor).
The custom DriveWorksEZ program contains a logic loop that fails to resolve, causing the drive's internal microprocessor to time out.
If the H66 error persists after reseating the hardware, checking parameter configurations, and isolating electrical noise, the problem may stem from a failed internal component. In such cases, contact an authorized Yaskawa service center or your local distributor to test the option card or control board for hardware replacement. Before touching any internal components, turn off the
On most modern Yaskawa VFD platforms—such as the GA700, GA500, A1000, and U1000 series—.
This comprehensive technical guide explains what the H66 error means, identifies its root causes, and provides step-by-step instructions to safely troubleshoot and resolve the issue. Understanding Yaskawa Error Code H66
within the drive's control board. Unlike mechanical faults that trigger based on physical load or voltage spikes, H66 indicates that the drive's internal "brain" has lost its place in the execution sequence or cannot verify incoming data from an integrated peripheral. Primary Cause Step 2: Inspect and Reseat the Option Card
: If your resistor has a built-in thermal switch, ensure it is wired correctly to the drive's digital inputs and that the switch hasn't tripped due to an actual overheat. Yaskawa America Technical Resources
The error on Yaskawa drives typically indicates a Digital Operator Communication Error , which occurs when the drive does not receive any data from the digital operator (keypad) for a specific duration. 1. Common Causes
Always isolate low-voltage control and communication cables from high-power motor leads by placing them in separate, grounded metal conduits.
: The host PLC or controller might have a programming error that activates both direction bits simultaneously during a cycle.