Cwfl-6000 Manual Info
Up to 14kW (depending on environmental conditions and water temperature). Dual Cooling Circuit:
Keeping your manual handy is great, but knowing the "greatest hits" of maintenance and setup will save you downtime. Here is the essential guide to mastering your CWFL-6000. 1. The Power of Dual Temperature Control The standout feature of the CWFL-6000 is its dual cooling circuits Low-Temperature Circuit: Dedicated to cooling the fiber laser source. High-Temperature Circuit: Designed for the laser head/optics.
Understanding the structural and electrical boundaries outlined in the official document is vital before configuring the hardware: Specification Details Designed explicitly for 6000W fiber lasers Cooling Accuracy Precise control within ±1∘Cplus or minus 1 raised to the composed with power C Default Voltage 380V AC (Three-Phase) at 50Hz / 60Hz Refrigerant Type Eco-friendly R-407C Water Pump Rating Heavy-duty 1.1 kW motor Internal Reservoir 70-liter capacity tank Net Weight (Dry) Approximately 200 kg (440 lbs) Digital Interfacing ModBus RS-485 communication protocol Unboxing and System Components
Supports Modbus-485 for real-time monitoring and integration with the laser system's control software. Installation & Operational Requirements cwfl-6000 manual
Install the chiller on a level, solid floor capable of supporting its full weight (with water).
CWFL-6000 Manual: Comprehensive Guide to TEYU S&A Fiber Laser Chiller
Place the unit on a flat, level floor capable of supporting its full operational weight. Electrical Connections Up to 14kW (depending on environmental conditions and
Clean the condenser fins with a soft brush or compressed air to ensure efficient heat dissipation. 6. Troubleshooting & Alarm Codes The CWFL-6000 has an alarm system to protect the laser. Alarm Code Potential Cause E1 Ultrahigh Room Temp Poor ventilation, high ambient temperature. E2 Ultrahigh Water Temp Overloaded chiller, dirty filter. E3 Ultralow Water Temp Ambient temperature too low. E4 Flow Alarm (Low) Water pipe blocked, pump failed. E5 Sensor Failure Temp sensor disconnected/damaged.
Use purified water, distilled water, or deionized (DI) water.
Exit settings and save parameters, or mute the alarm buzzer. Switching Between Constant and Intelligent Mode replace with a spare if necessary.
| | Fault Description | Check and Resolution | | :---------------- | :-------------------------------------------------- | :-------------------------------------------------------------------------------------------------------------------- | | E01 / E02 | Low/High Temperature System Flow Alarm | - Check the water level in the tank; top up if low. - Inspect for blocked or kinked water pipes. | | E05 / E07 | Water Temperature Too High Alarm | - Ensure the air filters and ventilation openings are not obstructed. - Check if the heat load exceeds capacity. | | E03 | Ambient Temperature Too High Alarm | - Improve ventilation. Ensure the operating environment is below 40°C. | | No Power | Unit Does Not Turn On | - Check the power cord connections. - Inspect the internal fuse; replace with a spare if necessary. |
Connect the "Inlet" of the chiller to the "Outlet" of your fiber laser source, and vice versa.
Water temperature dropped too low (often during startup in cold climates).
start the chiller without water in the tank. Fill it until the gauge hits the green area 3-Phase Check: If you see error codes E08 or E09