Autoclave Tomy Sx700 Manual Best Site
Ensure the exhaust drain bottle at the front or side of the machine is filled with clean water up to the designated low-level line. This condenses the steam vented during the cycle. 3. Operating Instructions and Cycle Selection
Fill the external exhaust drainage bottle with clean water up to the designated low-level mark. Ensure the exhaust hose is securely submerged in the bottle to condense escaping steam.
| Frequency | Action | Instructions | | :--- | :--- | :--- | | | Check water level | Refill reservoir with distilled water. | | Weekly | Clean the door gasket | Wipe with a soft, damp cloth; check for cracks. | | Monthly | Clean the strainer | Remove and clean the water intake filter inside the chamber. | | Every 50 cycles | Descaling | Run a "Clean" cycle with Tomy descaling agent (or citric acid). | | Every 6 months | Replace air filter | Located behind the front panel. | autoclave tomy sx700 manual best
Press the key. The unit will begin heating, and the display will show the real-time chamber temperature. 4. Maintenance and Cleaning Protocols
| Specification | Detail | Additional Info | | :--- | :--- | :--- | | | 69 L (Effective Internal Volume) | Internal Volume 79 L | | Chamber Dimensions | Ø 370 x 774 mm | Effective Use: Ø 360 x 675 mm | | Operating Temp. Range | Sterilizing: 105°C to 135°C | Heating: 45°C to 104°C; Warming: 45°C to 95°C | | Max Operating Pressure | 0.25 MPa | Analog pressure display | | Heating Element | 3.0 kW electric heater | 3 kW heater | | Exterior Dimensions | 470W x 528D x 1051H mm | Compact vertical footprint | | Weight | 72 kg (159 lbs) | Four swivel casters for mobility | | Power Requirements | Single phase, 220-240V, 15A | Plug-and-play, no plumbing required | | Key Safety Features | Lid Interlock, Over-heat Prevention, Over-pressure Prevention, Safety Valve, Water Level Sensor | Multiple redundant protections | Ensure the exhaust drain bottle at the front
The SX-700 operates as a self-contained system with an exhaust bottle, requiring no external plumbing.
The chamber temperature exceeded 137°C. Turn off the power, check for a faulty sensor, or ensure the chamber is not heavily overloaded. Over-Pressure Fault Operating Instructions and Cycle Selection Fill the external
The way to kill your SX-700 is to use tap water.
The Tomy SX-700 (ES-315) is a high-pressure, bench-top steam sterilizer designed for laboratory and clinical use. It utilizes saturated steam under pressure to achieve rapid sterilization of liquids (e.g., media, buffers), glassware, instruments, and biological waste. The "SX-700" model is renowned for its digital microprocessor control, large 50-liter chamber, and "One-Touch" operation.
Dissolves or warms pre-sterilized media without re-sterilizing it.