: Features a 32-bit ARM Cortex-M4F (80 MHz) microprocessor with 512 MB of non-volatile flash memory.
Rated for ambient temperatures ranging from 0 to 158°F (-17 to 70°C) with a non-condensing relative humidity range of 5 to 95%.
Compatible with intelligent wall sensors like the BACtalk Microset . hbt-bms-VLC-1600-E-datasheet.pdf
For more detailed installation diagrams and software configuration, refer to the Alerton VLC-1600 Technical Data .
| Specification | Detail | | :--- | :--- | | | Siemens Sinumerik 840 D | | Table Diameter | 1600 mm (63.0 inches) | | Max. Workpiece Diameter | 2000 mm (78.7 inches) | | Max. Workpiece Height | 1550 mm (61.2 inches) | | Max. Table Load | 8000 kg (17,600 lbs) | | Main Motor Power | 60/84 kW (80 kW / ~107 HP) | | Machine Weight | 25,000 kg (55,000 lbs) | | Machine Dimensions | 4.4m x 4.62m (approx. 14.4 ft x 15.2 ft) | vlc 1600 datasheet
All localized control algorithms, mathematical expressions, and automation sequences are configured using Alerton's proprietary graphical programming interface. System configurations compile into the standard BD4 DDC file format . Intelligent Sensor Support
The 16-bit universal inputs on the VLC-1600-E are software-configurable. Operators do not need to change physical jumpers to adapt each port to different sensor types. Input Type Electrical Rating / Requirement Common Application Examples Ωcap omega (Ibex) or 10k Ωcap omega Space temp, discharge air, water lines Dry Contact Clean, volt-free digital loop switching Relay status, pump runtime, safeties Voltage DC Dual range auto-detection: 0–5 VDC or 0–10 VDC Humidity sensors, static pressure sensors Current Loop 4–20 mA or 0–20 mA (Requires external 250- Ωcap omega Industrial transducers, gas detection Pulse Inputs Max frequency 100 Hz; min duty cycle 5ms ON / 5ms OFF Flow meters, electrical submetering Special Port Functions
: Used for simple status switches, fault indicators, and occupancy states.
: Operates on 24 VAC @ 50–60 Hz, with a minimum draw of 5 VA. : Features a 32-bit ARM Cortex-M4F (80 MHz)
: Internal logical loop time of 100 msec for high-speed processing.
The device uses a half-wave rectified 24 VAC power input. This electrical profile allows a single step-down transformer to power multiple VLC modules in parallel by grounding one leg of the 24 VAC line directly to the panel chassis. Additionally, a dedicated 20 VDC output (
The is a versatile, high-performance VisualLogic® Controller (VLC) designed for demanding building automation applications. As part of the BACtalk® suite, it offers advanced, programmable control for HVAC systems, central plants, and lighting, specifically built to handle numerous control points with high precision.
I can provide specific termination diagrams or calculation guidelines for your external resistors! Share public link hbt-bms-VLC-1600-E-datasheet
The newer model upgrades these inputs to a higher resolution of 16 bits . It also features a 24 VAC power supply and provides three terminals that supply up to 100 mA total of 24 VDC to power external transducers and devices.
Alerton VLC-1600 VisualLogic Unitary Field Controller, Input Monitoring Device [Refurbished] Go to product viewer dialog for this item.
Fully certified under UL Standard for Safety 916 (Open Energy Management Equipment), CE Mark (EMC Directive 89/336/EEC), and FCC Part 15. Procurement and Support
: Rated for operating temperatures between 0 to 158°F (-17 to 70°C) with 5 to 95% RH, non-condensing. Key Features and Compatibility
If you cannot find an official , the part may be: